Wiring the I/O cable

The following shows the leads that comprise the I/O cable.
(1) Power supply
This connects the 24 VDC (±10 %) power supply. When using a Sensor Controller
with a PNP output, the power supply terminal is also the common I/O terminal for all I/
O except for the linear output.
Supply power from a DC power supply unit that has a countermeasure (safety ultra-
low voltage circuit) built-in for preventing high voltages from occurring.
Wire the power supply separately from other devices. Wiring them together or placing
them in the same duct may cause induction, resulting in malfunction or damage.
(2) GND
The GND terminal is the 0 V power supply terminal. When using a Sensor Controller
with an NPN output, the GND terminal is also the common I/O terminal for all I/O
except for the linear output.
(3) OUT0 (HIGH output)
This outputs judgment results (HIGH).
(4) OUT1 (PASS output)
This outputs judgment results (PASS).
(5) OUT2 (LOW output)
This outputs judgment results (LOW).
(6) OUT3 (ENABLE output)
This turns ON when the Sensor Controller is ready for measurement. This output is
interlocked with the ENABLE indicator.
ZS-HL
2-10
User's Manual
(Cable length: 2 m)
Recommended power supply unit p.1-3
Brown
(1) Power supply
Blue
(2) GND
Red
(3) OUT0
Green
(4) OUT1
Black
(5) OUT2
Pink
(6) OUT3
Gray
(7) OUT4
Co-axial (black)
(8) Linear output
Shielded
(9) Linear GND
Yellow
(10) IN0
Light blue
(11) IN1
Purple
(12) IN2
White
(13) IN3
Orange
(14) Unused