A.1 Technical Data - Festo CPX-CM-HPP Electronic Manual

Cpx terminal, fhpp interface.
Hide thumbs Also See for CPX-CM-HPP:
Table of Contents

Advertisement

A. Technical appendix
A.1
Technical Data
Type
General technical data of the CPX terminal
Total number of axes
Device−specific diagnostics
Configuration support
LED indicator
Axis connection
Protocol
Baud rate
Fieldbus interface
Max. line length
CPX module code
Max. address capacity
Inputs
Outputs
Protection class
as per IP 60529, plug connector inserted
Nominal operating voltage
Operating voltage range
Intrinsic current consumption
at rated operating voltage
Power failure buffering
Product weight (without interlinking block)
Dimensions W x L x H
Festo P.BE−CPX−CM−HPP−E N en 0910NH
CPX−CM−HPP
See CPX System Description
P.BE−CPX−SYS−...
Max 4 axes per CPX−CM−HPP
Channel and module−oriented diagnostics
Undervoltage/short−circuit modules
Diagnostics memory
CPX−MMI
PL:
Power supply
Error
Error
CAN bus
FHPP
1 Mbit/s
Socket, M9, 5−pin
30 m
175
32 byte
32 byte
IP65
24 VDC
18 ... 30 V DC
typ. 80 mA
10 ms
approx. 140 g
50 mm x 107 mm x 55 mm
A−3

Advertisement

Table of Contents
loading

Table of Contents