4. Diagnosis and error treatment
Error
Designation and possible cause
no.
Error in the motor or output stage (CPX error category 109)
90
Motor stop
Internal error of the drive
91
Supply voltage error
Entrance bridge of the power supply
defective
Intermediate circuit defective
92
Overtemperature of the power stage
Internal error of the drive
93
Overtemperature motor
Temperature sensor in the motor
defective
Motor too hot
94
Short circuit in the power stage
Internal error of the drive
95
Motor temperature 5 °C below maximum
Internal error in the motor
2
96
I
t Error (motor)
Internal error in the motor
99
General unassignable error
Other errors
Tab. 4/2: Error messages of the CPX−CM−HPP