Festo CPX-CM-HPP Electronic Manual page 57

Cpx terminal, fhpp interface.
Hide thumbs Also See for CPX-CM-HPP:
Table of Contents

Advertisement

3. Commissioning
Festo P.BE−CPX−CM−HPP−EN en 0910NH
Format
Input and output format of the position value
Valid for:
Actual position
Setpoint position in the direct mode
Warning
Danger of injury to people and material damage.
If format specifications are set incorrectly, the setpoint
position can deviate from the real positions.
Check the format specifications carefully.
·
Value Format
0
32 bit [Ink]
1
32 bit [ m]
Significance
Only for CMMx−xx motor controller:
original 32 bit long integer of the motor
controller. When the factor group for
motor controller CMMx−xx is used,
this 32 bit value represents the path
(e.g. m) dependent on the set resolution
−3
(e.g. 10
).
Only for motor unit MTR−DCI and motor
controller SFC−xx:
The 32−bit position value is converted
into [ m] or [1/1000°].
3−21