3. Commissioning

3.6.3 Additional parameters

Festo P.BE−CPX−CM−HPP−EN en 0910NH
Function
Parameter
number
16 + 16 * m + 0
Module code
16 + 16 * m + 13
Version
784 + m * 4 + 0
Serial
number
784 + m * 4 + 1
784 + m * 4 + 2
784 + m * 4 + 3
Tab. 3/11: Additional parameters
Value Comment
175
Entry in the CPX system
table.
0 ...
Shows the output
255
status (version) of the
module corresponding
to the rating plate.
Byte 0: includes the
year and month of the
series.
The bytes 1 ... 3 include
per nibble a digit of the
per nibble a digit of the
serial number
(BCD coded).
(
d d)
3−23