Technical Data; Ambient Conditions; Technical Data, Mechanical - Festo VTSA-F-CB Instructions, Assembly, Installation

Hide thumbs Also See for VTSA-F-CB:
Table of Contents

Advertisement

Technical data

10
Technical data
10.1

Ambient conditions

The valves can be operated up to a temperature of -5 °C. At low temperatures, condensate and mois-
ture can freeze.
Recommendation:
To remove condensate and moisture, install a dryer.
Ambient conditions
Permissible temperat-
ure range
Long-term storage
Operation
Medium
Relative humidity
Degree of protection
(with cable from Festo
accessories)
Corrosion protection
Mounting position
Vibration resistance
Shock resistance
Tab. 13 Technical data: ambient conditions
10.2

Technical data, mechanical

Mechanical
Weights
Left end plate (CPX ter-
minal)
Complete CPX module
Pneumatic interface
38
[°C]
-20 
 60
...
[°C]
-5 
 50
...
[°C]
-5 
 50
...
[%]
 90
...
IP65
Corrosion resistance class CRC 0
As desired, with H-rail mounting, horizontal only
Transport application test with severity level 2 in accordance
with FN 942017-4 and EN 60068-2-6
Shock test with severity level 2 in accordance with FN 942017-5
and EN 60068-2-27
Width
18 mm
[g]
Approx. 80
[g]
Approx. 210
[g]
1470
26 mm
42 mm
Festo — VTSA-F-CB — 2019-08
52 mm

Advertisement

Table of Contents
loading