Technical data
10
Technical data
10.1
Ambient conditions
The valves can be operated up to a temperature of -5 °C. At low temperatures, condensate and mois-
ture can freeze.
Recommendation:
•
To remove condensate and moisture, install a dryer.
Ambient conditions
Permissible temperat-
ure range
–
Long-term storage
–
Operation
–
Medium
Relative humidity
Degree of protection
(with cable from Festo
accessories)
Corrosion protection
Mounting position
Vibration resistance
Shock resistance
Tab. 13 Technical data: ambient conditions
10.2
Technical data, mechanical
Mechanical
Weights
Left end plate (CPX ter-
minal)
Complete CPX module
Pneumatic interface
38
[°C]
-20
60
...
[°C]
-5
50
...
[°C]
-5
50
...
[%]
0
90
...
IP65
Corrosion resistance class CRC 0
As desired, with H-rail mounting, horizontal only
Transport application test with severity level 2 in accordance
with FN 942017-4 and EN 60068-2-6
Shock test with severity level 2 in accordance with FN 942017-5
and EN 60068-2-27
Width
18 mm
[g]
Approx. 80
[g]
Approx. 210
[g]
1470
26 mm
42 mm
Festo — VTSA-F-CB — 2019-08
52 mm