Festo CPX-CM-HPP Electronic Manual page 90

Cpx terminal, fhpp interface.
Hide thumbs Also See for CPX-CM-HPP:
Table of Contents

Advertisement

A. Technical appendix
1: CM−HPP
X−Axis: MTR−DCI
Y−Axis: CMMS−AS
Z−Axis: No axis
U−Axis: No axis
_____________________________________________________
Back
OK
1: CM−HPP :M.X
Process state
_____________________________________________________
I: Enabled
I: Open
I: Warn
I: Fault
I: 24VL
I: Lock
I: OPM1
I: OPM2
I: /Halt
I: MC
I: Ref
O: Enable
O: /Stop
O: /Brake
O: Reset
O: Lock
O: OPM1
O: OPM 2
O: /Halt
_____________________________________________________
Back
Force Mode
A−6
In the [Monitoring/Forcing (M)] menu, the current values of
some inputs and outputs of the connected motor controllers
are displayed. With the Force Mode" function, statuses of the
inputs and outputs can be forced.
The following I/O data are displayed for each axis:
Entry in the CPX−MMI
I: Enabled
I: Open
I: Warn
I: Fault
I: 24VL
I: Lock
I: OPM1
I: OPM2
O: Enable
O: /Stop
O: /Brake
O: Reset
O: Lock
O: OPM1
O: OPM2
O: /Halt
FHPP bit
SCON.B0
SCON.B1
SCON.B2
SCON.B3
SCON.B4
SCON.B5
SCON.B6
SCON.B7
CCON.B0
CCON.B1
CCON.B2
CCON.B3
CCON.B5
CCON.B6
CCON.B7
CPOS.B0
Festo P.BE−CPX−CM−HPP−E N en 0910NH

Advertisement

Table of Contents
loading