3. Commissioning
3.7

Force

3−28
Through forcing, you can compel input and output signals.
Actual input signals or changes in status by program are
ignored and replaced by the force values.
Warning
High forces of acceleration at the connected actuators!
Uncontrolled movements of the actuators can cause
collisions and severe injuries.
Be very careful when forcing in order to avoid
·
uncontrolled movements of the actuators.
Make sure that no persons are in the sphere of influence
·
of the drives or any other connected actuators.
The following options are available for forcing:
Handheld type CPX−MMI
Front end controller
Higher−order controller
Whether forcing is already possible after the system start can
be set via the CPX terminal.
Further information on forcing can be found in the
CPX system description, type P.BE−CPX−SYS−...