2. Fitting and installation

2.3

Axis connection (CAN bus interface)

M9 socket
Pin
1
2
3
4
5
Housing
1)
When using a connecting cable with open end, e.g. NEBC−M9W5−K−5−N−LE3.
Tab. 2/6: Pin allocation of the CAN bus interface
2−6
The motor controllers of the positioning system are
connected via the CAN bus to the axis connection of the
CPX−CM−HPP.
CAN bus parameters:
Transmission rate: 1 Mbit/s
Data profile: FHPP
Max. line length: 30 m
The axis connection of the CPX−CM−HPP is designed as a
5−pin M9 socket:
Signal
Wire colour
n.c.
n.c.
CAN_GND
Green
CAN_H
White
CAN_L
Brown
The CPX−CM−HPP does not provide power supply to the
connected CAN bus stations via the CAN bus interface.
1)
Explanation
Not connected
Not connected
CAN Ground
CAN High
CAN Low