One Ethernet Card, No Public Network Connection; Two Ethernet Cards, No Public Network Connection; Two Ethernet Cards, Public Network Connection - EMC Connectrix EC-1200 Planning Manual

2 gb/s enterprise storage network system
Table of Contents

Advertisement

One Ethernet Card,
No Public Network
Connection
Two Ethernet Cards,
No Public Network
Connection
Two Ethernet Cards,
Public Network
Connection
After completing the steps described under Common Steps for All
Configurations, perform these steps:
1. Log in to the Client service processor.
a. Enter a user name and password.
b. In the Connectrix field, enter the IP address of the Server
service processor (10.1.1.1 if you are following the suggested
examples in this appendix).
After completing the steps described under Common Steps for All
Configurations, perform these steps:
1. On the Server service processor, set the Silicom FastEthernet
CardBus adapter to manual startup:
a. Follow this path on the Windows NT desktop:
Start, Settings, Control Panel, Devices
b. Locate and click (to highlight) the FastEthernet adapter, then
click Startup.
c. On the Startup menu, click Manual, then click OK.
2. Reboot the Server service processor.
3. Log in to the Client service processor.
a. Enter a user name and password.
b. In the Connectrix field, enter the IP address of the Server
service processor (10.1.1.1 if you are following the suggested
examples in this appendix).
After completing the steps described under Common Steps for All
Configurations, log in to the Client service processor:
1. Enter a user name and password.
2. In the Connectrix field, enter the public IP address of the Server
service processor.
Upgrading to a Single Service Processor Environment
Consolidating Service Processors