Image Verification - Honeywell Galaxy Flex V3 Series Installer Manual

Table of Contents

Advertisement

Galaxy Flex Installer Manual

Image verification

Up to 5 Camera PIRs can be connected to the system in order to provide alarm verification
by the capture of a sequence of images at the time a sensor is activated. Both pre alarm and
post alarm images can be captured. The images can be transmitted to an ARC equipped with
a PE receiver.
Image capture on alarm activation
The camera PIR will record a set of images when triggered according to its setting's in
parameters menu [51.79]. The Camera can be triggered in the follow situations:
1.
In response to its own PIR sensor being activated while the zone is set.
2.
An alarm activation of any other zone which is linked to that camera address via
the zone's configuration (option 52.zone.15 within the zone programming). Note
that the zone associated with a Camera PIR must be in the same group as the
Camera PIR itself. Any zone type can be associated, including fire and hold-up
alarm types.
Notes for entry alarm
A sensor will always trigger the camera if activated while it is set. This includes sensors on
the entry route. However the panel will not process a picture sequence from an entrance
route sensor unless the entry timer expires without the system being unset.
Image capture of user who sets the system
A picture sequence can be recorded and sent to the ARC when the setting process is started
if the user who starts the setting process is enabled for video (menu option 42.1.user.11).
The keypad must be located within the viewing angle of the camera.
Installation of Camera PIRs
Camera PIRs should be installed as per the process for installing all other devices on the
Intellibus. See section 1 for details. See the separate instructions supplied with the device or
on the Literature CD (800-08338) regarding installation of the PIR sensor.
End of Line resistor
If the Camera PIR is installed as the last device on the cable then the end of line resistor
must be enabled by fitting the jumper link located below the screw terminal in the mounting
bracket. If the Camera PIR does not need the end of line resistor to be active then the jumper
link must be removed to ensure reliable operation.
Configuration
The following settings can be configured:
The LED
PIR sensitivity
Appendix G: Peripherals