Galaxy Flex Installer Manual
RF Stop Mode [51.60.7]
This option controls whether, and how, an RF fault prevents the panel from being set. There
are three options:
0=Disabled
1=Warning
2=Auto Check
RF Learn Alert [51.60.8]
This option controls whether an audible alert is given when RF devices are learned onto the
system (this affects menus 42.1.x.10.1 and 52.2.x.11.1):
0=Disabled
1=Enabled
Activity Mon [51.61]
Use this option to check zone activity. If zones programmed for zone activity checks are not
activated within the programmed time period, and/or number of set/unset cycles, a zone
masked fault is indicated at the panel. Six different combinations of check criteria are
available for each zone.
Each criteria type can be programmed to check the number of days, the set/unset cycles or
both. The default value is both.
1=Mode
2=MAX Period
3=MAX Unsets
Lockout [51.62.1]
Use this option to set the number of invalid code attempts that can be made before keypad
lockout occurs. Keypad lockout prevents any entry via all keypads associated with the
groups assigned to the keypad where the invalid attempts were made. The lockout lasts for
5 minutes. If you are locked out, and after the lockout period, you can make another x
invalid code attempts before being locked out again, where x is the lockout value.
Entry of a valid code resets the lockout counter. The number of lockout attempts between
each lockout can be programmed between 0 and 10. The default is 5 and 0 disables the
function.
An RF fault will not prevent setting
If there is a failure the user will get a warning but can continue to set
If there is a failure the system cannot be set until the zone(s) have been
activated
No audible tones given
If the device is learned on, then a double beep is given at the keypads
and sounder. If the signal strength is low then a long continuous beep is
given as a warning.
The mode can be set to one of three options: Max Period, Max Unsets
or Either.
The time period that zone activity is checked can be set to between 1
and 28 days. The default is 14 days.
This is the number of programmable set/unset cycles that must take
place before a zone masked fault is indicated at the panel. The number
of set/unsets can be programmed from 1 to 10. The default is 7.
Parameters [51]
99