Honeywell Galaxy Flex V3 Series Installer Manual page 158

Table of Contents

Advertisement

Keypad [58]
Buzzer Mimic [58.3]
Use this option to program the keypad buzzer to mimic the function of the programmed
keypad output (refer to Program Outputs [53]). The default function of the keypad output
is entry/exit horn and the default Mimic defaults to On, therefore the keypad buzzer operates
as an entry/exit horn at factory setting.
To disable the keypad buzzer from mimicking the output select 0=Off.
Backlighting [58.4]
Use one of the following options to set the keypad backlighting:
0
Always off
1
Always on (default)
2
On when the system is unset
Off when the system is set
On when keys are pressed
On during setting and unsetting
3
On when keys are pressed
Off after keypad timeout and menu exit
4
On when keys are pressed
Off after keypad timeout and menu exit
Keypad Mute [58.5]
Use this option to improve security and reduce tampering with the keypad when it is located
in a public place.
0=Off
(default).
1=On
The keypad remains silent and no backlight or key press symbols are displayed
until a valid code is entered.
Keypad Disable
A keypad may be disabled by programming the address of the keypad as a link destination
(refer to Links [54]). When the source of the link is activated the keypad does not respond
to any key press, however, the LCD, keypad buzzer and any keypad output device act as
normal.
Hot Keys [58.6]
Use this option to enable Hot Keys (1=Enabled, 0=Disabled). When enabled three pairs of
hot keys that can be used to activate the following alarms:
PA alarm – press
Emergency alarm – press
Fire alarm – press
158
and
2
and
5
and
8
Galaxy Flex Installer Manual