Appendix G: Peripherals
Wiring the MAX
4
The MAX
unit can be connected to the control
panel in online or standalone configuration. The
diagram opposite provides details for both
configurations.
4
The MAX
relay is configured in either the NC
or NO configuration depending upon the variant
purchased (MX04-NC, MX04-NO).
Note: An external relay may be required when
using a.c. powered locks.
x
P
3
MAX
Figure 12 MAX
Specification
Supply Volts
Nominal Current
Maximum Current
Maximum Switching Current
Security Grade
Environmental Class
ACE type
Weight (boxed)
Dimensions (box)
238
4
1 = Read (Amber)
2 = Open (Green)
3 = Closed (Red)
4 = Nightlock (Red)
5 = Add (Red)
6 = Void (Red)
7 = Program (Red)
4
LEDs
12 V d.c.
35 mA
50 mA
1 A @ 30 V d.c. max.
3
IV
B
267 g
185 x 120 x 48 mm (LxBxH)
Galaxy Flex Installer Manual
Suppressor
Relay Out
Violet
OR
Suppressor
Relay Out
Violet
Door Contact I/P
Grey
Egress I/P
Green
Extra Ground
Brown
Ground
Black
Horn O/P
Grey/Pink
Power Input
Red
RS485A In
White
RS485B In
Yellow
RS485A Out
Pink
RS485B Out
Blue
Spare
Red/Blue
Figure 13 Connection diagram
+12V
Relay Module
A060
C
+
NC
-
NO
+12V
Door Lock
Door Contact
Egress
+12V
Horn
+12V
Galaxy RS485
Data Bus -
only used
in on-line
configuration