Galaxy Flex Installer Manual
Program Zones [52]
If the Line Fail zone is active at the point of setting, a warning message is displayed. The
user can choose to continue or abort the setting procedure. It is also possible to prevent the
system setting if the Line Fail is active by enabling the Stop Set parameter (option 51.18).
25 AC Fail
This function is used to monitor a remote power supply. In the event of a power failure the
AC Fail zone is activated; the activation (+) and de-activation (–) of the zone is recorded in
the event log.
26 Log
This zone type has no operational function. It is designed to record the activation of a zone
in both the set and unset state. The activation (+) and de-activation (–) of Log zones is
recorded in the event log.
28 Video
This function is identical to the Intruder function, with the exception that the cumulative
number of activations from Video zones, before a full alarm is generated, is programmable.
The number of activations required is determined by the Video parameter (option 51.30).
The range is 1 to 9. The activation count is incremented when any Video zone in the group
activates. The count is reset to zero when the group is unset.
29 Video Exit
This function is identical to the Video function, with the exception that the user can activate
the zone during setting and unsetting without incrementing the Video activations count. The
Video output is not activated during setting and unsetting.
32 Set Log
This function is identical to the Log function, with the exception that zone activations are
only recorded in the event log during the set period.
33 Custom A
This function allows a zone to be assembled. The functionality of the zone (when it
activates; the outputs activated; if it sets or unsets the systems; if it logs) are assigned using
Assemble Zones [64]. Once the Custom A zone has been created, it can be assigned to as
many zones as required.
34 Custom B
This function is identical in operation and assembly to Custom A.
39 Keyswitch Reset
The Keyswitch Reset function allows alarms to be cancelled and the system to rearm
without unsetting the system. The type of reset authorization is determined by the
Keyswitch Level [51.14]. The type required to reset Intruder, PA and Tamper alarms is
determined by the System Reset, Tamper Reset and PA Reset parameters (options 51.06,
51.07 and 51.22) respectively.