Galaxy Flex Installer Manual
Codes [42, Quick Menu 7]
A single entry of a dual code, without a second dual code entry within 60 seconds, is
recorded in the event log as an Illegal Code; all outputs programmed as Illegal Code are
activated.
Dual Focus
If a MAX number for the same user has a # assigned the dual function only works between
the PIN and the MAX card of the same user.
Dual Access Cards
If a user's card number is assigned a # the card becomes dual access and requires a second
PIN or card to open the door (see To assign a dual code in Modify PIN [42.1.User code.1]).
Dual Focus (card held)
If a card has a # assigned to the number, then any card-held function will only work in
conjunction with the PIN from the same user, provided that the PIN has a # assigned also.
The Dual function works in either order, but if you enter the PIN first, you have setting
access only and not menu access. If you present the card first, you have setting access and
menu access (see Codes [42] for programming).
Modify Level [42.1.User code.2]
Each user is assigned an access level that controls which menu options can be accessed. The
programmable levels are from 0 to 6.
6 is assigned to the manager.
7 is assigned to the engineer – this is fixed and cannot be assigned to user codes.
8 is assigned to the remote code. This is fixed and cannot be assigned to the engineer or user
codes. The remote code can only be used via keypads addressed as E.