Honeywell Galaxy Flex V3 Series Installer Manual page 254

Table of Contents

Advertisement

Galaxy Flex Installer Manual
Appendix G: Peripherals
Image settings.
All setting will be done through the control panel configuration, menu option 51.79
Specifications:
Detection Range: 11 m x 12 m
Pet/Animal Immunity: 36kg, 18kg, 0 kg
Installation Height (centre of lens): 2.30 m to 2.70 m (2.30 m is the ideal height)
Power Supply: TBA
Tamper Switches: Cover: Opening; Wall: Wrenching off wall.
White Light Immunity: 6,500 Lux (min.)
Sensitivity: Selectable (Lowest, Low, Medium and High)
Temperature: Operational: -10° to 55° C, Storage: -20° to 70° C
Relative Humidity: 5% a 95% Without condensation
Temperature Compensation: Dual Slope
Supervision: Yes, controlled by the alarm panel.
PIR Detection Field: Pyroelectric dual element. Pet Immune Lens: 44 long range, 36
intermediate, 18 lower.
Dimensions: 11.2 cm x 6.0 cm x 4.0 cm
Weight: Product 220g Packaged 280g
Accessories Included: Screw
Battery life: 5 years
Standards
EN 50131-1 and TS 50131-2-2
Grade 2; Environmental Class II
Certified NF&A2P according to C48433 Type 2
CNPP Cert & CNMIS. Cert. No: 2620002850A0
Note: In EN 50131-2-2 compliant installations, mount the sensor at 2.30 m, select the high
sensitivity setting and use the cover screw (supplied).