Honeywell Galaxy Flex V3 Series Installer Manual page 113

Table of Contents

Advertisement

Galaxy Flex Installer Manual
normally used in conjunction with a Push Set zone, which acts as the exit terminator for the
setting procedure.
Pressing
when programming an Entry zone doubles the entry time of the group.
Opening an Entry zone during the exit time is reported on the keypad as an open zone, and
the entry/exit horns bleep rapidly to indicate that the zone is open.
08 Push Set
This zone function is used to terminate the setting routine. The system sets when the Push
Set zone, usually a push button, is activated. The entry/exit horn stops immediately when the
button is pressed and the system sets after four seconds, allowing the doors to settle to the
closed state. The Push Set zone remains inactive until the next setting routine.
Note: The Push Set zone can be either 1 k going to 2 k or 2 k to 1 k - refer to
Installation Manual (II1-0033), System Architecture for wiring details. The first time
that the Push Set is used to terminate the setting, the button needs pressing twice.
The first press identifies the normal status of the button to the system.
Activating a Push Set zone during the exit time is not reported on the keypad as an open
zone.
Note: The termination feature of a Push Set zone can be extended to terminate the setting
of multiple groups by pressing
Star
Group Function.
09 Keyswitch
Use the Keyswitch function to use a zone as an on/off switch for the system or assigned
groups. Operating a Keyswitch zone when the system is unset starts the timed full setting
routine and the exit time is applied. The system sets when the exit time expires or a Final or
Push Set is activated.
Note: Assign a
to the Keyswitch zone function to cause the Instant setting routine to be
#
activated. In this case the exit time is not applicable. If a Keyswitch Zone has its
omit attribute enabled, activation of the Keyswitch force sets the assigned groups.
When the Keyswitch is activated twice during the exit time of an autoset, the autoset is
temporarily cancelled for a few seconds, then it restarts the exit time causing the panel to
reset.
Operating a Keyswitch zone type during the pre-warn period of an autoset starts a Force Set.
If you then activate the switch again (i.e. unset with Keyswitch) before the panel sets, the
pre-warn continues on the autoset.
Note: When the Keyswitch is activated the second time to take the panel back into pre-
warn, it can be up to 10 seconds before the pre-warn tones at the keypad start up
again.
If the system is set, operating a Keyswitch immediately unsets the assigned groups and there
is no entry time countdown.
when assigning a group to the zone. Refer to the
Program Zones [52]