Galaxy Flex Installer Manual
Parameters [51]
Language [51.17.3]
Use this option to select the keypad display language.
Press
to change the display immediately.
ent
Cold Start [51.17.4]
Use this option to set all defaults back to factory settings.
Stop Set [51.18]
Use this parameter to prevent the system from set override if there is a communication or
power fail condition at the time of starting the setting procedure. If the condition is the result
of an open Line Fail or AC Fail zone, the system cannot be set until the zone is closed or
omitted. The Stop Set default is disabled (set to 0).
Note: Battery Low also prevents the system from setting.
Part Alarm [51.19]
Use this parameter to enable the Bells and Strobe outputs to activate if an alarm condition
occurs when the system is part set. Select 1 to enable and 0 the disable.
Note: The Horn, Entry/Exit and Intruder outputs are not affected by this parameter.
You can assign a different value to each group.
Power Delay [51.20]
Use this parameter to delay activation of the AC Fail signal following a mains failure. This
is to allow the mains to return before signalling a fault.
The default is 10 minutes and the range is 0 to 600 minutes.
You can assign a different value to each group.
Reset MGR [51.21]
Use this option if the Master Manager code is lost or must be replaced.
When you select the Reset MGR parameter the system displays WARNING!!! ENT=Code
Change
Press
to erase current code and reset it to the default of 1234.
ent
91