Galaxy Flex Installer Manual
When the system is full set operation is identical to the Exit zone function.
When the system is part set operation is identical to the Entry zone function.
Pressing
when programming a Part Entry zone doubles the entry time of the group.
13 PA
The PA (Personal Attack) function is continuously operational. Activation of this zone type
overrides the Bell Delay parameter and causes an instant full alarm condition. A PA Reset
authorized code is required to reset the condition (refer to Parameters [51], 22=PA Reset).
Intruder outputs are not activated by PA zones.
Note: If a PA zone is open, it is indicated on the keypad whenever a valid code is entered.
The group that the open PA is assigned to cannot be set until it is closed.
14 PA Silent
The PA Silent function is identical to the PA function, with the exception that there is no
audible or visible indication of the activation; that is, no bells or strobes are activated. Only
the PA output (normally channel 2 on the digital communicator) signals the alarm. The
activation (+) and restoral (–) of PA Silent zones is recorded in the event log.
Notes:
1.
At the time of setting, any PA Silent zones that are currently open are reported to the
user.
2.
Engineer mode cannot be exited if a PA Silent zone is open.
15 PA Delay
The PA Delay function is identical to the PA function, with the exception that the PA output
activation can be delayed for up to 60 seconds and is set with the PA Delay [51.13] option.
During the period of delay the entry/exit horns activate to remind the user that the PA Delay
is counting down. Entering a valid code or closing the PA Delay zone aborts the alarm.
Note: If a PA Delay zone is open, it is indicated on the keypad whenever a valid code is
entered. The group that the open PA Delay is assigned to cannot be set until it is
closed.
16 PA Delay Silent
The PA Delay Silent function is identical to the PA Delay function, with the exception that
there is no audible or visible indication of the activation; that is, no bells or strobes are
activated. Only the PA output (normally channel 2 on the digital communicator) signals the
alarm. The activation (+) and restoral (–) of PA Delay Silent zones are recorded in the event
log.
Note: At the time of setting, any PA Delay Silent zones that are currently open are
reported to the user.
Program Zones [52]
115