Phone Line Connections

Connect incoming phone line and handset wiring
to the main terminal block (via an RJ31X jack) as
shown in the Summary of Connections diagram at
the back of this manual. Wire colors represent the
colors of the cable to the RJ31X jack.
Alternative Communications Media
(ACM) Connections
Connect the data in/data out terminals and
voltage input terminals of the ACM to the
control's keypad connection points.
Set the ACM's address to "03" following the
instructions provided with the ACM.
Audio Alarm Verification
Connections (AAV, "Listen-In")
Refer to the connection diagram below.
Connections use one of the on-board triggers.
Suggested AAV Module:
ADEMCO UVS (shown) or Eagle 1250
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
SWITCH
BANK 1
1 = OFF
2 = OFF
3 = OFF
4 = OFF
5 = OFF
6 = OFF
7 = OFF
8 = ON
2-18
CONTROL
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
UVCM
MODULE
SWITCH
BANK 2
1 = ON
2 = ON
3 = OFF
FALLING VOICE TRIG
4 = ON
5 = ON
6 = ON
7 = ON
8 = ON
GND
+12VDC IN
Figure 13. Connection of AAV Unit
Notes
• If you are using an Audio Alarm Verification
(AAV) unit, refer to Audio Alarm
Verification (AAV) section for special
wiring connections.
CAUTION: To reduce the risk of fire, use only
0.6mm O.D. or larger telecommunication line
cord for phone line connections.
Notes
• Use compatible ACMs (e.g., 7845i,
7845C/7835C [in Latin America], AI4164RS,
AI4164ETH).
Notes
• Set field *91 for AAV and program the
appropriate output (output 17 or 18) using
*80 Menu mode (select zone type "60").
• For voice session monitoring, connect an
EOLR zone to UVCM module terminals 6 &
7, and program the zone as zone type 81 (*56
Menu mode).
E.g., Using output 18 for the trigger, program
an output function in *80 Menu mode as:
ZT = 60, P = 0, Action = 1, Device = 18
TRIGGER
5
CONNECTOR
ZONE
TERMINALS
21
22
23
4
5
EOL
RING
TIP
OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)
EARTH
GROUND
24 25
RED (R)
GREEN (T)
RJ31X
GREY (R)
BROWN (T)
TO
PREMISES
HANDSET
INCOMING
PHONE LINE