VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
1∗ ∗ ∗ ∗ 49
Suppress Transmitter
Supervision Sound
0 = disable
1 = enable
1∗ ∗ ∗ ∗ 52
Send Cancel If Alarm + Off
(partition-specific)
0 = disable
1 = enable
1∗ ∗ ∗ ∗ 53

Disable Download Callback

0 = callback required
1 = no callback required
1∗ ∗ ∗ ∗ 55
International Date Format
0 = disable (mm/dd/yy)
1 = enable (dd/mm/yy)
1∗ ∗ ∗ ∗ 56
AC 60Hz/50Hz
0 = 60Hz
1 = 50Hz
1∗ ∗ ∗ ∗ 57
Enable 5800 RF Button Global
Arm
0 = disable
1 = enable
1∗ ∗ ∗ ∗ 58
Enable 5800 RF Button Force
Arm
0 = disable
1 = enable
1∗ ∗ ∗ ∗ 60

Zone 5 Audio Alarm Verification

0 = disable
1 = enable
1∗ ∗ ∗ ∗ 70

Event Log Types

0 = disable
1 = enable
1∗ ∗ ∗ ∗ 71
12/24 Hour Type Stamp Format
0 = 12-hour
1 = 24-hour
1∗ ∗ ∗ ∗ 72
Event Log Printer On-Line Mode
0 = disable
1 = enable
1∗ ∗ ∗ ∗ 74

Relay Timeout XXX Minutes

Enter 000-127 times 2 minutes (000-254).
1∗ ∗ ∗ ∗ 75

Relay Timeout YYY Seconds

Enter 000-127 seconds.
5-10
EXPLANATION
If enabled, no trouble soundings occur on the keypad for transmitter check-in
failures.
Must be 0 for UL.
If enabled, Cancel reports are sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
If disabled, Cancel reports are sent within Bell Timeout period only.
NOTES:
This option must be enabled so Cancel reports are always sent.
Select whether a callback from the control panel is required for downloading.
Must be 0 for UL installations.
Select the date format for display in the event log.
Select the frequency for the AC.
Must be set to 0 for U.S. and Canadian installations.
If enabled, the system arms/disarms in accordance with the button's user's
global arming settings.
If enabled, allows the RF button user to force a bypass of all faulted zones
when arming the system.
NOTE: When attempting to arm the system, the keypad beeps once after the
button is pressed if any faulted zones are present.
Force Arming is not a ULC Listed feature and
U LC
must be disabled for ULC installations.
If enabled, zone 5 is used for 2-way audio (AAV).
Must be 0 for UL installations.
NOTE: Zone 5 cannot be used as protection zone.
This field has five entries as follows: Alarm, Check, Bypass, Open/Close and
System. If enabled, the system logs those events into the event log.
Select the type of time stamping for the event log.
If enabled, the system prints the events as they occur.
If disabled, the system prints the log only upon request.
This is used for #80 Menu Mode Time-Driven event relay command numbers
"04/09" and Output Programming in the #93 Menu Mode Programming output
command "56."
This is used for #80 Menu Mode Time-Driven event relay command numbers
"05/10" and Output Programming in the #93 Menu Mode Programming
command "57."