Full Test; Program Codes; Instruct The End User - Honeywell Galaxy Flex V3 Series Installer Manual

Table of Contents

Advertisement

Full Test

Full Test
Use this menu option to select and test up to two zones under full set conditions, including
remote signalling. All remaining zones, except for permanently active zones such as PA and
Fire, are inactive during the test.
To perform a full test:
1.
Select Full Test (
2.
Press
or
to move to the zone you wish to test, or type its number, and then press
A
B
. An option to select a second zone is displayed.
ent
3.
Do one of the following:
To test a single zone only, press
procedure and no further action is required.
To add a second zone to the test, press
prompts to start the test.
4.
Activate the selected zones and check for the correct response.
To end the test:
Unset the system.

Program codes

Modify PIN (
42 ent 1 ent 1 ent
Modify level (
42 ent 1 ent 2 ent
Modify name (
42 ent 1 ent 3 ent
Modify groups (
Card number (
42 ent 1 ent 6 ent
MAX function (
card/fob/tag/button
Learn fob (
42 ent 1 ent 10 ent 1 ent
Enable PA function if required
Add Batch (
42 ent 2 ent 1 ent

Instruct the end user

Show the end user how to set and unset the system with reference to the Flex Quick User
Guide.
34
).
62 ent
) – change user PIN codes
) – control the options a user can access
) – name the user
) – control which groups the user can access
42 ent 1 ent 5 ent
) – enter the unique card number
) – assign a single menu option to a
42 ent 1 ent 7 ent
) – program a number of tags or cards
Galaxy Flex Installer Manual
(No). The system starts the full setting
B
(Yes), and then follow any further
A
) – assign a keyfob to a user

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy flex 20 v3Galaxy flex 50 v3Galaxy flex 100 v3

Table of Contents