Honeywell Galaxy Flex V3 Series Installer Manual page 121

Table of Contents

Advertisement

Galaxy Flex Installer Manual
4=Diag Recording
Enable this attribute so that it is used during the diagnostic test (see Record [61.2.3]). This
test can also be carried out remotely.
5=Descriptor
Use this attribute to assign a descriptor of up to 12 characters to each output.
6=Control
Use this attribute to allow users to control the state of certain panel outputs from the
TouchCenter. There are two options:
1=Mode
Each lighting output can be controlled by setting to 0=OFF, 1=Toggle or
2=Trigger.
If the Control is set to Toggle or Trigger for an output, it will be
controllable via the TouchCenter whose group map contains the output's
group. If the Control is set to OFF it cannot be controlled or viewed by
the TouchCenter.
2=Show Status
The status can be either 0=OFF or 1=ON. When set to ON the light
shows the state of the output.
7=Output Groups
Note: The Groups attribute is only available if groups have been enabled on the system
(refer to Options [63]).
Use this attribute to assign the output to groups on the system. An output can be assigned to
more than one group. All outputs default to all groups on the system.
When you select the attribute, the groups that the output is currently assigned to are
displayed. Press the relevant number keys to toggle the status of the group and press
If the group number is displayed on the top line, the group is assigned to the output.
If a dash (–) is displayed in place of the group number, the group has been removed from the
output.
The output activates if triggered by an event in any of the groups assigned to that output
unless output group status has been programmed.
Group Status
This group attribute offers an additional feature that makes the operation of the output
conditional on the set status of each of the system groups. An output assigned Group Status
only activates if the set conditions of the programming are met, for example, an Intruder
output used to trigger a communicator can be programmed to activate only if groups 2 and 4
are set and group 3 is unset.
Groups
12345678
STATUS >-SUS----
Program Outputs [53]
.
ent
121

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy flex 20 v3Galaxy flex 50 v3Galaxy flex 100 v3

Table of Contents