Remote Access [47]
Control Upload Eng Prog [47.4.5.1]
Initiates a connection when engineer programming has been modified.
Control Upload User Prog [47.4.5.2]
Initiates a connection when user programming has been modified.
Control Upload Either [47.4.5.3]
Initiates a connection when engineer or user programming has been modified.
Remote Maint [47.4.6]
Use this option to control the mode for automatically initiating communications for remote
routine inspection and maintenance. The panel uploads only the most recent information
available from Diagnostics [61]. No other panel programming is uploaded. There are two
sub-options that control this.
Remote Maintenance Schedule [47.4.6.1]
Use this option to control the schedule for the initiation of communication for remote
routine inspection. The schedule can be set from 0 to 365 days. The default is 0 days, which
disables the function.
Remote Maintenance Advice [47.4.6.2]
Use this option to control the communication initiation method. It can be initiated
automatically by the schedule programmed above or manually by user entry of the Service
PIN code, with or without a notification message. There are three options. The default value
for each is disabled.
1=Code Only
2=Code + Notice
3=No Code/Notice Enables a remote servicing session without the need for a Service PIN
Service Pin [47.4.7]
This is a 6-digit numeric code (default 987654), which initiates an automated call to the
Remote Servicing application. The Service PIN code can only be changed from Remote
Servicing. It is sent to the panel via the Send Remote Access Start Code. The Service PIN
code cannot be the same as any other user codes in the system. This option is only available
80
Entry of a Service PIN code automatically initiates a remote servicing
connection to call back number 1. The Service PIN code can only be
modified by remote users. When the Service PIN code is entered, it
resets any scheduled connection timers.
Enables the remote servicing notification timer and display of remote
servicing notification. The remote service notification message is not
displayed if the system is set. It only becomes active when the panel is
unset. The message REMOTE CALL INIT, A=SP PIN ENTER is
displayed after entry of a valid manager type user code.
code and the panel's remote servicing notification message. This option
uses the start and end times programmed in option 47.4.2.1 and
47.4.2.2.