Galaxy Flex Installer Manual
Program Outputs [53]
11 Spare (Latch)
Use this function for outputs that are not being used on the system.
12 Ready (Reflex)
The Ready output is active when all zones in the system (group) are closed, and activates in
both the unset and set conditions.
13 Security (Latch)
This output is activated whenever a Security zone is activated. The output is not subject to
the Re-arm parameter. It latches on and remains active until a valid code (type 2 or above) is
entered.
14 AC Fail (Reflex)
This output indicates the status of the a.c. (mains) power supply. The output activates when
the a.c. supply fails or an AC Fail zone is activated. It is reset when the a.c. supply is
restored or the AC Fail zone is closed. Activation is delayed subject to the time entered in
20=Power Delay.
15 Battery Low (Reflex)
This output activates whenever the control unit stand-by battery falls below 10.5 V or a
Battery Low zone is activated. It is restored when the voltage rises above 10.5 V or the
Battery Low zone is closed.
16 Fire (Latch)
This output is activated whenever a Fire zone is activated. The output is not subject to the
Re-arm parameter. It latches on and remains active until a valid code (type 2 or above) is
entered.
17 Horn (Latch)
This output is a general alarm output and is activated by most zone types in both the local
and full alarm modes. For example, a Fire zone activation causes the Horn output to pulse
on and off – on for 0.5 seconds, off for 0.1 seconds. The Horn output is subject to the Bell
Time, Bell Delay and No. Re-arm parameters.
18 E/E Horn (Latch)
The entry/exit horn output has a dual function:
In an alarm condition its function is identical to that of the Horn output.
128