Pre-Checks [66] - Honeywell Galaxy Flex V3 Series Installer Manual

Table of Contents

Advertisement

Pre-checks [66]

Pre-checks [66]
This option provides added system security by alerting the user to zones that may not be
operating correctly.
Note: Pre-check does not operate when the system is in the engineer mode.
Testing Zones
The entry/exit horns beep once when each zone is tested. As each zone is successfully
tested, the keypad indicates the number that remains to be tested. When the last zone is
successfully tested the entry/exit horn sounds twice and the keypad displays 0 CHECK
ZONES; press
to resume the system routine.
ent
1=Mode
The Mode determines the pre-check level that the selected zones are subjected to before the
system can set. The Mode is selected from one of the following:
Disabled (default): the pre-check option is disabled; even if zones are selected, they are not
checked.
Warning: when the setting routine is started the user is informed of the number of selected
pre-check zones that have not been activated since the system was unset. Press
view the zones. Press
activated do not have to be tested.
Autocheck: when the setting routine is started the user is informed of the number of
selected pre-check zones that have not been activated since the system was unset and a
warning is sounded; press the
before setting can be resumed.
Forced Check: when the setting routine is started the keypad indicates the number of pre-
check zones that are on the system; to view the pre-check zone addresses press
of the preselected zones must be tested before setting can take place.
2=Select Zones
When you select the option, the address and function of the first zone on the system is
displayed. Use
or
A
status of the pre-check attribute of the zone press
included in the pre-check by displaying PRE-CHECK ZONE. Select other zones to be pre-
checked in the same way. Once all of the zones have been selected, press
180
16 CHECK ZONES
A=VIEW
to continue the setting routine. The zones that have not been
ent
or
keys to view the zones. These zones must be tested
A
B
0 CHECK ZONES
ENT=VIEW
to select a zone, or enter the zone address directly. To toggle the
B
Galaxy Flex Installer Manual
. The keypad indicates that the zone is
#
or
to
A
B
or
. All
A
B
.
esc

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy flex 20 v3Galaxy flex 50 v3Galaxy flex 100 v3

Table of Contents