Set With Cards/Tags/Fobs - Honeywell Galaxy Flex V3 Series Installer Manual

Table of Contents

Advertisement

Galaxy Flex Installer Manual
Set with a keyswitch
A keyswitch starts the setting procedure of each of the groups assigned to the keyswitch
zone. At the end of the exit time or when the setting procedure is terminated by a final or
push-set zone closing, the entry/exit horn and keypad buzzers become silent for six seconds,
then emit two long tones to confirm that the system is set.
Note: If the keyswitch has its Part attribute enabled (Refer to the Program Zones [52]
option) then the keyswitch part sets the system.
Unset with a keyswitch
Activating a keyswitch, when the group that it is assigned to is set, instantly unsets the
group. All other groups that have been 'starred' to the keyswitch are also unset.

Set with cards/tags/fobs

Proximity cards can be used to set and unset the system. You do this by assigning one of the
setting options (refer to MAX Function [42.1.7]) to a user.
When a card is held against a MAX module or KeyProx for 3 seconds, the card held
function programmed to the card user is activated. For access control readers, a function
button or triple swipe is required to activate the card function.
If the card user has a keypad assigned, the function is shown at the assigned keypad.
If the card user has no keypad assigned then all keypads in the group assigned to the card
user display Press any Key.
If a key is pressed the keypad containing the key to be pressed shows the card held
function.
If no keys are pressed all keypads in the group(s) allocated to the card show the held
menu function.
If the card user has group choice all groups available to the user are displayed on the
keypad. The user must select the groups to be set/unset/part set using the appropriate
number keys, as per normal PIN users.
If the card user has no group choice then the card held setting function starts automatically.
Unset with Proximity Cards
The system or groups can be unset using proximity cards with MAX, KeyProx modules and
access control readers.
If the unsetting procedure has been started by activating a final or entry zone, then swiping
the card unsets the system.
If the card user has group choice, then only the group assigned to the final or entry zone is
unset. All other groups available to the user are displayed on the programmed/selected
keypad or KeyProx.
Note: The reader module and the proximity card user must have common groups to allow
the card held function to be activated.