Connect outputs

The wiring of the terminator and keyswitch zone type is shown in the following figure:
Connect outputs
Outputs are addressed in the same way as the zones. If using on-board outputs, connect and
address as follows:
O/P
Address
1
1001
2
1002
3
99
If required, use the Program Outputs menu (

Secure the tamper circuits

1.
If an external siren/bell/warning device is fitted, connect the tamper return line from the
device to the T terminal.
2.
If an external siren/bell/warning device is not fitted, connect the T terminal directly to
the 0 V terminal.
3.
If a relay output is required, fit the Output Option Board.
4.
Replace and secure the panel cover.
20
Figure 7 Terminator and keyswitch zone wiring
Function
Bells
Strobe
Exit/Entry (E/E) horn
Figure 8 A typical application
Galaxy Flex Installer Manual
O/P type
Open-collector,
switched negative
Open-collector,
switched negative
AC audio to drive an
internal loudspeaker
) to modify the default settings.
53 ent
Connection
Connect load between OP1
and +12 V
Connect load between OP2
and +12 V
Connect load (8–32 )
between OP3 and +12 V