state disable
state enable
write
Bluetooth serial 1 (bluetooth-line:1) level commands
auto show statistics
bluetooth serial <line>
clear line counters
clrscrn
command mode always
command mode echo
serial string disable
command mode echo
serial string enable
command mode serial
string
command mode serial
string <string>
command mode signon
message <string>
command mode wait
time <milliseconds>
default line mode
default threshold
exit
gap timer <milliseconds> Sets the gap timer in milliseconds. If some data has been received, it will be forwarded
interface bluetooth-
rfcomm
kill session
line <line>
line mode serial device
name <text>
no clear line counters
no command mode
no command mode si-
gnon message
no gap timer
no name
protocol none
protocol tunnel
show
show bluetooth line
show command mode
show history
show statistics
SGX™ 5150 IoT Device Gateway Command Reference
Disables Bluetooth.
Enables Bluetooth.
Stores the current configuration in permanent memory.
Continuously displays line statistics.
Enters the bluetooth serial level. <line> = number of the line (bluetooth serial port) to be
configured.
Sets the serial counters to zero.
Clears the screen.
Sets the current line to always be in command mode.
Disables user-defined serial boot string to be echoed in the CLI.
Enables user-defined serial boot string to be echoed in the CLI.
Enables user to enter a custom string at boot time to enter command mode.
Sets a string that can be entered at boot time to enter command mode. <string> = text with
possible binary characters. Within [] use binary decimal up to 255 or hex up to 0xFF. Within
{} specify decimal milliseconds time delay.
Sets a sign-on message that is sent from the serial port when the device boots and when
the line is in command mode. <string> = text with possible binary characters. Within [] use
binary decimal up to 255 or hex up to 0xFF.
Sets boot-up wait time for command mode serial string. <milliseconds> = wait time.
Restores the default line mode.
Restores the factory default threshold.
Exits to the enable level
after this time since the last character.
Sets the line interface to bluetooth-rfcomm.
Kills command mode session on the Line
Enters the line level. <line> = number of the line (serial port) to be configured.
Sets the line to serial device mode.
Sets the name for this line.
Restores the serial counters to the aggregate values.
Disables command mode for the current line.
Clears the signon message displayed at boot time and when entering command mode.
Removes the gap timer, so forwarding depends on the line speed.
Removes the name of this line.
Uses no protocol on the line.
Applies tunnel protocol on the line.
Displays the current status.
Displays the current configuration.
Shows the command mode settings for the current line.
Displays the last 20 commands entered during the current CLI session.
Shows the line statistics.
5: Commands and Levels