Lantronix SGX 5150 Command Reference Manual page 312

Iot device gateway
Hide thumbs Also See for SGX 5150:
Table of Contents

Advertisement

command mode echo
serial string disable
command mode echo
serial string enable
command mode serial
string
command mode serial
string <string>
command mode signon
message <string>
command mode wait
time <milliseconds>
configure current settings Configures line with the current value of settings.
data bits 7
data bits 8
default baud rate
default data bits
default flow control
default parity
default stop bits
default threshold
default xoff char
default xon char
exit
flow control hardware
flow control none
flow control software
gap timer <milliseconds> Sets the gap timer in milliseconds. If some data has been received, it will be forwarded
kill session
line <line>
name <text>
no clear line counters
no command mode
no command mode si-
gnon message
no gap timer
no name
parity even
parity none
parity odd
protocol modbus ascii
protocol modbus rtu
protocol none
protocol tunnel
SGX™ 5150 IoT Device Gateway Command Reference
Disables user-defined serial boot string to be echoed in the CLI.
Enables user-defined serial boot string to be echoed in the CLI.
Enables user to enter a custom string at boot time to enter command mode.
Sets a string that can be entered at boot time to enter command mode. <string> = text with
possible binary characters. Within [] use binary decimal up to 255 or hex up to 0xFF. Within
{} specify decimal milliseconds time delay.
Sets a sign-on message that is sent from the serial port when the device boots and when
the line is in command mode. <string> = text with possible binary characters. Within [] use
binary decimal up to 255 or hex up to 0xFF.
Sets boot-up wait time for command mode serial string. <milliseconds> = wait time.
Uses seven bits for data on the line.
Uses eight bits for data on the line.
Restores the default speed of 9600 bits per second.
Restores the default of eight data bits.
Restores the default of no flow control.
Restores the default of no parity.
Restores the default of one stop bit.
Restores the factory default threshold.
Restores the default xoff character on this line.
Restores the default xon character on this line.
Exits to the enable level
Uses hardware (RTS/CTS) flow control on the line.
Does not provide flow control on the line.
Uses software (xon/xoff characters) flow control on the line.
after this time since the last character.
Kills command mode session on the Line
Enters the line level. <line> = number of the line (serial port) to be configured.
Sets the name for this line.
Restores the serial counters to the aggregate values.
Disables command mode for the current line.
Clears the signon message displayed at boot time and when entering command mode.
Removes the gap timer, so forwarding depends on the line speed.
Removes the name of this line.
Uses a parity bit on the line for even parity.
Does not use a parity bit on the line.
Uses a parity bit on the line for odd parity.
Applies Modbus ASCII protocol on the line.
Applies Modbus RTU protocol on the line.
Uses no protocol on the line.
Applies tunnel protocol on the line.
5: Commands and Levels
312