Lantronix SGX 5150 Command Reference Manual page 356

Iot device gateway
Hide thumbs Also See for SGX 5150:
Table of Contents

Advertisement

bluetooth serial <line>
break duration <millisec-
onds>
clrscrn
default break duration
default terminal type
echo disable
echo enable
exit
exit connect menu disa-
ble
exit connect menu ena-
ble
line <line>
login connect menu disa-
ble
login connect menu ena-
ble
no send break
preview connect menu
send break <control>
show
show history
terminal <line>
terminal network
terminal type <text>
tunnel <line>
usb <line>
write
terminal 2 (config-terminal:2) level commands
bluetooth serial <line>
break duration <millisec-
onds>
clrscrn
default break duration
default terminal type
echo disable
echo enable
exit
exit connect menu disa-
ble
exit connect menu ena-
ble
SGX™ 5150 IoT Device Gateway Command Reference
Enters the bluetooth serial level. <line> = number of the line (bluetooth serial port) to be
configured.
Sets how long a break should last when it is being sent to the line. <milliseconds> = num-
ber of milliseconds.
Clears the screen.
Restores the break duration to the default value (500 ms).
Sets the default terminal type, 'UNKNOWN'.
Disables echoing of characters received on the line back to the line.
Enables echoing of characters received on the line back to the line.
Exits to the configuration level.
On the login connect menu, removes the menu item allowing the user to exit to the CLI.
On the login connect menu, inserts the menu item allowing the user to exit to the CLI.
Enters the line level. <line> = number of the line (serial port) to be configured.
Disables the login connect menu, so a user will get the CLI immediately after logging in.
Enables the login connect menu, so a user will get the menu rather than the CLI immedi-
ately after logging in.
Removes the configured send break character.
Shows the layout of the connect menu with current settings.
Sets the optional send break character. <text> = the character. The character may be input
as text, control, decimal, or hex. A control character has the form <control>C. A decimal
value character has the form \99. A hex value character has the form 0xFF.
Displays the current configuration.
Displays the last 20 commands entered during the current CLI session.
Enters the configure-terminal level. <line> = number of the terminal line (serial port) to be
configured.
Enters the configure-terminal level for the network.
Sets the terminal type.
Enters the tunnel level. <line> = number of the tunnel line (serial port) to be configured.
Enters the usb level. <line> = number of the line (usb port) to be configured.
Stores the current configuration in permanent memory.
Enters the bluetooth serial level. <line> = number of the line (bluetooth serial port) to be
configured.
Sets how long a break should last when it is being sent to the line. <milliseconds> = num-
ber of milliseconds.
Clears the screen.
Restores the break duration to the default value (500 ms).
Sets the default terminal type, 'UNKNOWN'.
Disables echoing of characters received on the line back to the line.
Enables echoing of characters received on the line back to the line.
Exits to the configuration level.
On the login connect menu, removes the menu item allowing the user to exit to the CLI.
On the login connect menu, inserts the menu item allowing the user to exit to the CLI.
5: Commands and Levels
356

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SGX 5150 and is the answer not in the manual?