ping interval <minutes>
show
show history
write
usb 1 (usb-line:1) level commands
auto show statistics
baud rate <bits per sec-
ond>
bluetooth serial <line>
clear line counters
clrscrn
command mode always
command mode echo
serial string disable
command mode echo
serial string enable
command mode serial
string
command mode serial
string <string>
command mode signon
message <string>
command mode wait
time <milliseconds>
data bits 7
data bits 8
default baud rate
default data bits
default flow control
default line mode
default parity
default stop bits
default threshold
default xoff char
default xon char
exit
flow control hardware
flow control none
flow control software
gap timer <milliseconds> Sets the gap timer in milliseconds. If some data has been received, it will be forwarded
interface usb-cdc-acm
kill session
line <line>
line mode ethernet de-
SGX™ 5150 IoT Device Gateway Command Reference
Sets the ping interval.
Shows the current configuration.
Displays the last 20 commands entered during the current CLI session.
Stores the current configuration in permanent memory.
Continuously displays line statistics.
Sets the line speed. <bits per second> = the speed. Standard speeds include 1200, 2400,
4800, 9600, 19200, and so on.
Enters the bluetooth serial level. <line> = number of the line (bluetooth serial port) to be
configured.
Sets the serial counters to zero.
Clears the screen.
Sets the current line to always be in command mode.
Disables user-defined serial boot string to be echoed in the CLI.
Enables user-defined serial boot string to be echoed in the CLI.
Enables user to enter a custom string at boot time to enter command mode.
Sets a string that can be entered at boot time to enter command mode. <string> = text with
possible binary characters. Within [] use binary decimal up to 255 or hex up to 0xFF. Within
{} specify decimal milliseconds time delay.
Sets a sign-on message that is sent from the serial port when the device boots and when
the line is in command mode. <string> = text with possible binary characters. Within [] use
binary decimal up to 255 or hex up to 0xFF.
Sets boot-up wait time for command mode serial string. <milliseconds> = wait time.
Uses seven bits for data on the line.
Uses eight bits for data on the line.
Restores the default speed of 115200 bits per second.
Restores the default of eight data bits.
Restores the default of hardware (RTS/CTS) flow control.
Restores the default usb line mode.
Restores the default of no parity.
Restores the default of one stop bit.
Restores the factory default threshold.
Restores the default xoff character on this line.
Restores the default xon character on this line.
Exits to the enable level
Uses hardware (RTS/CTS) flow control on the line.
Does not provide flow control on the line.
Uses software (xon/xoff characters) flow control on the line.
after this time since the last character.
Sets the usb line interface to USB-CDC-ACM.
Kills command mode session on the Line
Enters the line level. <line> = number of the line (serial port) to be configured.
Sets the usb line to ethernet device mode.
5: Commands and Levels
363
Need help?
Do you have a question about the SGX 5150 and is the answer not in the manual?