Siemens LOGO! Series Manual page 329

Hide thumbs Also See for LOGO! Series:
Table of Contents

Advertisement

Number
Output type
Electrical isolation
In groups of
Control of a digital input
Output voltage
Output current
Short circuit-proof and overload-
proof
Short circuit current limitation
Derating
Short circuit-proof cos 1
Short circuit-proof cos 0.5 to 0.7
Parallel output circuit for power
increase
Protection of output relay (if
desired)
Switching rate
Mechanical
Electrical
Ohmic load/lamp load
Inductive load
1)
LOGO!
Manual, 04/2011, A5E03556174-01
When LOGO! 24/24o, LOGO! 24C/24Co, LOGO! DM8 24 or LOGO! DM16 24 are switched on,
signal 1 is sent to the digital outputs for about 50 μs. Take this into account, especially when using
devices that react to short pulses.
A.5 Technical data: LOGO! DM8 24 and LOGO! DM16 24
LOGO! DM8 24
4
Transistor,
current-sourcing
1)
No
- -
Yes
≤ Supply voltage
max. 0.3 A
Yes
Approx. 1 A
none; across the entire
temperature range
- -
- -
Not permitted
- -
- -
10 Hz
10 Hz
0.5 Hz
Technical data
LOGO! DM16 24
8
Transistor,
current-sourcing
(1)
No
- -
Yes
≤ Supply voltage
max. 0.3 A
Yes
Approx. 1 A
none; across the entire
temperature range
- -
- -
Not permitted
- -
- -
10 Hz
10 Hz
0.5 Hz