Programming LOGO!
3.1 Connectors
LOGO! has the following connectors :
Inputs
Outputs
lo
hi
x
Flags
Shift register bits
Network inputs
Network analog
inputs
Network outputs
Network analog
outputs
DM: Digital module
AM: Analog module
1)
72
Connectors
LOGO! 230RCE
LOGO! 230RC/RCo
LOGO! 24RC/RCo
LOGO! 12/24RCE
LOGO! 12/24RC/RCo
LOGO! 24/24o
LOGO! 24C/24Co
Q1 to Q4
Logical '0' signals (off)
Logical '1' signals (on)
An existing connection that is not used
Digital flags: M1 to M27
Analog flags:
AM1to AM6 (0BA6)
AM1to AM16 (0BA7)
S1 to S8 (0BA6)
S1.1 to S4.8 (0BA7)
NI1 to NI64 (0BA7 only)
1)
NAI1 to NAI32 (0BA7 only)
1)
NQ1 to NQ64 (0BA7 only)
1)
NAQ1 to NAQ16 (0BA7 only)
1)
To make these four connectors available in a LOGO! 0BA7, you must configure them in the circuit
program with LOGO!Soft Comfort V7.0 and download the circuit program to the LOGO! 0BA7
device.
Two groups:
I9 to I24
I1 to I4 and I5 to I8
I1, I2, I3-I6, I7, I8
I9 to I24
AI3, AI4 ... AI1, AI2
Q5 to Q16 none
Manual, 04/2011, A5E03556174-01
AI1 to
none
AI8
AI5 to
AI8
AQ1,
AQ2