■ Arbitrary point radiation coordinate and time: PRD
Sets arbitrary point radiation X/Y coordinates, radiation time and laser power correction ratio.
Setting of arbitrary point radiation coordinate and time
STX
PRD
Setting of radiation time, and laser power correction only
STX
PRD
Delete of arbitrary point radiation condition
STX
PRD
Readout request of arbitrary point radiation coordinate and time
STX
PRD
Readout data of arbitrary point radiation coordinate and time
STX
PRD
When there is no setting data in the selected line, [Radiation time], [Laser power correction], [X position] and [Y position]
fields are not existed.
Data length
Name
Point radiation
condition No.
Line No.
Start line
End line
Radiation time
Laser power
correction
X position
Y position
* For the detail of the model type, refer to "Target laser marker" (P.4).
Reference
• The coordinate numbers that can be set or read out at once are max. 50 points.
78
[Point radiation condition No.] [Start line]
[Radiation time] [Laser power correction]
S
[X position] [Y position] [• • •] [X position] [Y position]
[Point radiation condition No.] [Line No.]
S
[Radiation time] [Laser power correction]
[Point radiation condition No.] [Start line] [End line]
S
[Point radiation condition No.] [Line No.]
R
[Point radiation condition No.] [Line No.] [Radiation time]
A
[Laser power correction] [X position] [Y position]
[byte]
2
"00"–"15"
3
"000"–"049"
3
"000"–"049"
3
7
"00000.1"–"99999.9" [ms]
3
"000"–"999" [%]
Model type*
8
LP-Sxx0(W)
LP-Sxx5(W)
LP-Sxx2
LP-Mxx0/LP-Zxx0
8
LP-Mxx5
LP-Mxx6/LP-Zxx6
15+16n-byte
15-byte
8-byte
5-byte
Max. 31-byte
Description
Setting range [mm]
"-045.000"–"+045.000"
"-080.000"–"+080.000"
"-027.500"–"+027.500"
"-060.000"–"+060.000"
"-110.000"–"+110.000"
"-165.000"–"+165.000"
ME-LPMSZ-SR-9
(Check sum)
Delimiter
(Check sum)
Delimiter
(Check sum)
(Check sum)
Delimiter
(Check sum)
Remarks
Indicates the correction value for
laser power specified at the laser
setting.
Delimiter
Delimiter