Marking Energy Range: Men; Setting / Readout Data Marking Energy Upper/Lower Limits; Readout Request Out Marking Energy Upper/Lower Limits - Panasonic LP-M Series Serial Communication Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

■ Marking energy range: MEN

[Supported models: LP-Mxxx/LP-Sxxx]
Sets thresholds for determination of whether the result of marking energy measurement is in the normal range.

Setting / Readout data marking energy upper/lower limits

STX
MEN
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.

Readout request out marking energy upper/lower limits

STX
MEN
Data length
Name
[byte]
Upper limit
9
Lower limit
9
110
Sub
[Upper limit] [lower limit]
18-byte
R
(Check sum)
Description
"000000000": OFF
"000000100"–"999999999" [mJ]
If the upper limit is not "000000000", the
lower limit should be less than the upper
limit.
(Check sum)
Delimiter
ME-LPMSZ-SR-9
Delimiter
Remarks
Sets the threshold of the marking energy.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents