Line Width: Wdc; Setting / Readout Data Of Line Width; Readout Request Of Line Width - Panasonic LP-M Series Serial Communication Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

■ Line width: WDC

Sets the width necessary to avoid crossing at marking intersection.

Setting / Readout data of line width

Sub
STX
WDC
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.

Readout request of line width

STX
WDC
R
Data length
Name
Line width
Uniform spot mode
(Effective only
LP-M / LP-Z series)
XY field
(LP-M series only)
Z position
(LP-M series only)
[Line width] [Uniform spot mode] [XY field] [Z position]
Max. 6-byte (LP-Sxxx/LP-SxxxW/LP-Zxxx),
Max. 13-byte (LP-Mxxx)
(Check sum)
Delimiter
Description
[byte]
5
"0.010"–"2.000" [mm]
• LP-Sxxx(W)
"0"
• LP-Mxxx / LP-Zxxx
"0": Off
(1)
"1": N-plane (Near Plane)
"2": B-plane (Base Plane)
"3": F-plane (Far Plane)
"4": Custom (LP-M series
only)
Model type* Setting range [mm]
LP-Mxx0
(3)
LP-Mxx5
LP-Mxx6
"-022"–"+022" [mm]
(-22 mm is the same position of
(4)
F Plane and +22 mm is the same
of N-plane.)
The line width for crossing avoidance at the
crossing point of marking line is indicated.
• LP-Sxxx/LP-SxxxW:
As this item is not available for the LP-S
series, set to "0" or no data.
• LP-Mxxx/LP-Zxxx:
To keep a uniform diameter of the laser spot
within the marking field, specify this mode.
The spot size is adjusted to the selected
plane.
The laser spot will have the same diameter in
the area between N-plane and the selected
plane.
Input only when the "4: Custom" is selected in
the Uniform Spot Mode for LP-M series.
Specify the length of X and Y axis for the
"000"–"120"
marking field, in which the laser spot size is
"000"–"220"
kept to be uniform.
"000"–"330"
The center position of the XY field is always the
center of the original marking field.
Input only when the "4: Custom" is selected in
the Uniform Spot Mode for LP-M series.
Specify the Z position to which spot diameter
the laser spot size in the specified XY field is
adjusted.
The laser spot will have the same diameter in
the area between N-plane and the selected Z
position.
ME-LPMSZ-SR-9
(Check sum)
Delimiter
Remarks
99

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents