Setting Method Of Remote Mode; Remote Mode State At Powered On - Panasonic LP-M Series Serial Communication Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

4.
With DIP switch No. 5, select the setting method of the remote
mode.
DIP switch No. 5
ON
OFF(initial setting)
Reference
• When DIP switch No. 5 is ON, the remote switch on the controller is not available.
5.
When DIP switch No. 5 is OFF, select the remote mode state at
powered ON with DIP switch No. 6.
DIP switch No. 6
ON
OFF (initial setting)
Reference
• When DIP switch No. 5 is ON, keep DIP switch No. 6 OFF.
• When DIP switch No. 6 is ON, "X5: REMOTE IN" signal on I/O terminal is not available.
CAUTION
6.
If you want to use the command format compatible with the former models of LP-F10/LP-F10W
series, select the command mode using DIP switch No. 7 and No. 8.
Standard Mode
No. 7: OFF
No. 8: OFF
Notice
• Even with the use of LP-F10/F10W mode, there is a difference in communication processing time and I/O operation
timing between older model of LP-F10/LP-F10W and LP-M/LP-S/LP-Z series.
7.
Install the DIP switch cover to the controller.
Notice
• A plastic cover is installed on the DIP switch. Install this cover always to avoid the dust penetration to the controller.
8.
Turn ON the power of laser marker.

Setting method of remote mode

Use the input signal of REMOTE IN (X5) on I/O terminal.
Use the remote switch on the front of the controller.

Remote mode state at powered ON

Starts up with remote mode ON
Starts up with remote mode OFF
• If the DIP switch No. 5 or No. 6 are used while turned on, construct a system
for re-pumping the laser manually as safety protection measures after the stop
of the laser radiation due to an emergency stop or an interlock.
LP-F10 Mode
No. 7: ON
No. 8: OFF
ME-LPMSZ-SR-9
LP-F10W Mode
No. 7: OFF
No. 8: ON
13