■ Data Matrix code marking condition: DMF

Sets the marking condition for Data Matrix code.
Set the Data Matrix code marking condition.
STX
DMF
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.

Readout request of Data Matrix code marking condition

STX
DMF
Data length
Name
Data Matrix No.
Data input mode
Number of row
Number of column
X position
Y position
Rotation angle
Module H.
Module W.
*1 : Available combination of number of row and column:
Auto
: 00 × 00
Square
: 10 × 10, 12 × 12, 14 × 14, 16 × 16, 18 × 18, 20 × 20, 22 × 22, 24 × 24, 26 × 26,
 32 × 32, 36 × 36, 40 × 40, 48 × 48, 52 × 52, 64 × 64, 72 × 72, 80 × 80, 88 × 88
Rectangle : 08 × 18, 08 × 32, 12 × 26, 12 × 36, 16 × 36, 16 × 48
*2 : For the detail of the model type, refer to "Target laser marker" (P.4).
Reference
• The Data Matrix No. 4 to 7 cannot be set and read out. (NAK09 is returned.)
• Readout is available only when the Data Matrix is set to the bar code type.
(When other bar code is set, NAK15 is returned.)
• In readout response, the digit of 1μm or 0.01° is rounded down.
• When the setting is performed using this command, the layer No. is "0".
144
[Data Matrix No.] [Data input mode]
Sub
[Number of row] [Number of column] [X position]
[Y position] [Rotation angle] [Module H.] [Module W.]
[Data Matrix No.]
R
1-byte
[byte]
1
"0"–"3"
"0": Binary
1
"1": Kanji
"00" or "08"–"88"
2
(Combination of number of row and column
is limited. *1)
"00" or "10"–"80"
2
(Combination of number of row and column
is limited.*1)
Model type*2
7
LP-Sxx0(W)
LP-Sxx5(W)
LP-Sxx2
LP-Mxx0 / LP-Zxx0
7
LP-Mxx5
LP-Mxx6/LP-Zxx6
6
"-180.0"–"+180.0" [°]
5
"0.001"–"1.000" [mm]
5
36-byte
(Check sum)
Description
Setting range [mm]
"-045.00"–"+045.00"
"-080.00"–"+080.00"
"-027.50"–"+027.50"
"-060.00"–"+060.00"
"-110.00"–"+110.00"
"-165.00"–"+165.00"
ME-LPMSZ-SR-9
(Check sum)
Delimiter
Remarks
Type of character to be encoded in
the Data Matrix code.
Longitudinal symbol size (the number
of modules) of the Data Matrix code.
When "0" is specified for the number
of both row and column, the symbol
size is encoded in the minimum size.
Lateral symbol size (the number of
modules) of the Data Matrix code.
Specifies the center coordinate of the
code.
Interval of module in longitudinal
direction.
Interval of module in lateral direction.
Delimiter