Laser Check Radiation: Spt; Setting Of Laser Check - Panasonic LP-M Series Serial Communication Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

■ Laser check radiation: SPT

Controls "Laser check radiation" for laser radiation at the center of the marking area.

Setting of laser check

STX
SPT
Data length
Name
Laser check
radiation
Reference
• This command is available only when the DIP switch No. 2 on the rear side of the controller is ON.
• You can start the laser radiation only when the laser pumping is completed and the shutter is closed or the "command
reception mode ON" is set by Command reception permission (MKM) command.
• The laser is radiated at the center position.
• The laser power can be changed by setting the laser condition.
• For LP-Z series, even without "stop" or "interrupt" command, the laser radiation automatically stops after about one
minute and the shutter is closed.
• For LP-Mxxx-S type, laser can not be emitted without opening the laser gate. After starting the radiation, open the laser
gate by external control signals. Refer to the "Safety / Setup / Maintenance Guide" for detail.
• For LP-Mxxx-S type, "laser gate open request output" signal will be ON to start the radiation and "laser gate close
request output" signal will be ON after finishing the radiation for the specified one-shot time.
• Do not control other operation or setting with "Stop radiation temporarily" status. Laser radiation should be ended with
"Stop radiation" status.
• Do not execute any other operation during the laser radiation.
112
[Laser check radiation]
S
1-byte
Description
[byte]
"0": Stop radiation
"1": Start radiation
1
"2": Stop radiation
temporarily
(Check sum)
• The internal shutter is automatically opened and
closed at the time of start and stop of radiation.
• "Stop radiation temporarily" refers to the status
stopping radiation with the shutter opened. Use this
state only when restarting radiation in a while.
• To restart the radiation after sending "2" (Stop
radiation temporarily), send "1" without closing the
shutter.
ME-LPMSZ-SR-9
Delimiter
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents