Sphere (Data Length: 63-Byte) - Panasonic LP-M Series Serial Communication Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

3. Sphere (Data length: 63-byte)

Data length
Name
Layer No.
Work shape
Center position X
Center position Y
Center position Z
Rotation angle X
Rotation angle Y
Rotation angle Z
Diameter
Defocus
* For the detail of the model type, refer to "Target laser marker" (P.4).
Reference
• Set the defocus value so that the sum of the Z coordinate to be actually marked and the defocus value is in the range of
the interwork distance (specification value) +/-22.000 mm (LP-M) or +/-25.000 mm (LP-Z).
88
[byte]
2
"00"–"15"
"7": Sphere convex
1
"8": Sphere concave
8
Model type*
LP-Mxx0/LP-Zxx0
8
LP-Mxx5
8
LP-Mxx6/LP-Zxx6
7
"-090.00"–"+090.00" [°]
7
"-090.00"–"+090.00" [°]
7
"-180.00"–"+180.00" [°]
Model type*
LP-Mxx0/LP-Zxx0
7
LP-Mxx5
LP-Mxx6/LP-Zxx6
Model type*
8
LP-Mxxx
LP-Zxxx
Description
Setting range [mm]
"-060.000"–"+060.000"
"-110.000"–"+110.000"
"-165.000"–"+165.000"
Setting range [mm]
"001.000"–"120.000"
"001.000"–"220.000"
"001.000"–"330.000"
Setting range [mm]
"-022.000"–"+022.000"
"-025.000"–"+025.000"
ME-LPMSZ-SR-9
Remarks
The center coordinate of 3D work is
indicated.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents