Signals Of Rs-232C Connector; Connecting To External Control Devices; Rs-232C Connector; External Controller - Panasonic LP-M Series Serial Communication Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

■ Signals of RS-232C connector

Terminal No.
Signal
1
Reserve
2
RxD (RD)
3
TxD (SD)
4
Reserve
5
GND (SG)
6
Reserve
7
8
9

■ Connecting to external control devices

• To connect the laser marker to the PC for control, use a commercially available RS-232C cross cable (9-pin).
• In case of connecting to PLC, a type of the cable (straight or cross) differs depending on a manufacturer or a model.
Please follow the PLC manual.
• To connect RS-232C terminal without using a commercially available RS-232C cable, connect only 3 signals of RxD,
TxD and GND and do not use other signals on the laser marker side.
• The external controller may need a signal line connection (loop back line) other than RxD, TxD, or GND on the external
control device side depending on the specifications of the external control device. Read the instruction manual of the
external control device and connect it to the laser marker appropriately.
Connection example
* The loop back wiring on the external control device side shown in the above figure is just an example. The wiring
method varies depending on the specifications of each external control device. Read the instruction manual of the
external control device and connect it to the laser marker appropriately.
18
Function
Do not use this terminal.
Receiving data: Connect TxD (SD) of the external control device.
Transmission data: Connect RxD (RD) of the external control device.
Do not use this terminal.
Signal ground: Connect GND (SG) of the external control device.
Do not use this terminal.

RS-232C connector

(Laser marker)
Terminal No.
Signal
2
RxD
3
TxD
5
GND

External controller

Signal
Cross cable
RxD
TxD
GND
DCD
DTR
DSR
*
RTS
CTS
ME-LPMSZ-SR-9
Terminal No.
2
3
5
1
4
6
7
8

Hide quick links:

Advertisement

Table of Contents
loading