Step & Repeat Condition: Src; Model Type* Setting Range [Mm] Lp-Sxx0(W) Lp-Sxx5(W) Lp-Sxx2; Model Type* Setting Range [Mm] Lp-Sxx0(W) "000.000"-"090.000" Lp-Sxx5(W) "000.000"-"160.000" Lp-Sxx2 - Panasonic LP-M Series Serial Communication Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

■ Step & repeat condition: SRC
Sets the condition of "Step & repeat" to mark the same marking contents on multiple locations in one file.
Setting / Readout data of general condition
Set the step & repeat condition for specified number with the following format:
Sub
STX
SRC
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
Readout request of general condition
STX
SRC
R
Data length
Name
[byte]
Step &
1
repeat
Number of
3
row
Number of
3
column
Row step
7
Column step
7
X offset
(8)
Y offset
(8)
Base
2
position
Counter
update at
2
each step
* For the detail of the model type, refer to "Target laser marker" (P.4).
Reference
• When the step and repeat setting is set to "None," the step and repeat setting can be omitted. If data is input and that
data is out of the setting range, response data for abnormal receiving is returned.
• When the data is readout under the step & repeat is set to "none", the subsequent fields following to "number of row" is
not readout.
[Step & repeat] [Number of row] [Number of column]
[Row step] [Column step] [X offset] [Y offset]
[Base position] [Counter update at each step]
Max. 41-byte
(Check sum)
Delimiter
Description
"0": OFF
"1": ON
"001"–"400"
(number of row x column < 4000)
Model type*
LP-Sxx0(W)
LP-Sxx5(W)
LP-Sxx2
LP-Mxx0 / LP-Zxx0
LP-Mxx5
LP-Mxx6/LP-Zxx6
Model type*
LP-Sxx0(W)
"-045.000"–"+045.000"
LP-Sxx5(W)
"-080.000"–"+080.000"
LP-Sxx2
"-027.500"–"+027.500"
LP-Mxx0 / LP-Zxx0
"-060.000"–"+060.000"
LP-Mxx5
LP-Mxx6/LP-Zxx6
"-165.000"–"+165.000"
"00": Upper left
"01": Upper right
"10": Lower left
"11": Lower right
"00": Same in all steps
"11": Missing number and marking laterally direction
"12": Missing number and marking lengthways direction
"21": Sequential number and marking laterally direction
"22": Sequential number and marking lengthways
direction
ME-LPMSZ-SR-9
Setting range [mm]
"000.000"–"090.000"
"000.000"–"160.000"
"000.000"–"055.000"
"000.000"–"120.000"
"000.000"–"220.000"
"000.000"–"330.000"
Setting range [mm]
"-110.000"–"+110.000"
(Check sum)
Delimiter
Remarks
Marking the same data is
repeated to the X or Y axis
direction.
The number of repeated
marking to Y direction
The number of repeated
marking to X direction
The marking pitch to the Y
direction is specified.
The marking pitch to the X
direction is specified.
Specifies X/Y Offset of the
reference step.
(If both values of X&Y offsets
are "0", X/Y off setting can be
omitted.)