For Itf/Code39/Nw-7 - Panasonic LP-M Series Serial Communication Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

3. For ITF/CODE39/NW-7

Data length : 60-byte (LP-Mxxx / LP-Sxxx / LP-Zxxx), 57-byte (LP-SxxxW)
Data length
Name
Bar code No.
Layer No.
Code type
System
reservation
Inversion
Check character/
start/stop
character
Bar code height
Narrow element
X position
Y position
Tilt angle
Quiet/
narrow element W
Wide/
narrow element W
Laser power
correction
Scan speed
correction
(Laser pulse cycle
correction)
* For the detail of the model type, refer to "Target laser marker" (P.4).
60
[byte]
2
"00"–"15"
2
"00"–"15"
"00": CODE39
2
"01": ITF
"03": NW-7
1
"0"
"0": Do not invert
1
"1": Invert
• For CODE39, ITF
"0": Check character absence
"1": Check character presence
1
• For NW-7
"A"–"D": Check character absence
"a"–"d": Check character presence
Model type*
LP-Sxx0(W)
LP-Sxx5(W)
7
LP-Sxx2
LP-Mxx0/LP-Zxx0
LP-Mxx5
LP-Mxx6/LP-Zxx6
5
"0.050"–"1.000" [mm]
Model type*
8
LP-Sxx0(W)
LP-Sxx5(W)
LP-Sxx2
LP-Mxx0/LP-Zxx0
8
LP-Mxx5
LP-Mxx6/LP-Zxx6
7
"-180.00"–"+180.00" [°]
4
"00.0"–"20.0"
3
"1.8"–"3.4"
3
"000"–"999" [%]
3
"001"–"999" [%]
(3)
"001"–"999" [%]
Description
Setting range [mm]
"001.000"–"090.000"
"001.000"–"160.000"
"001.000"–"055.000"
"001.000"–"120.000"
"001.000"–"220.000"
"001.000"–"330.000"
Setting range [mm]
"-045.000"–"+045.000"
"-080.000"–"+080.000"
"-027.500"–"+027.500"
"-060.000"–"+060.000"
"-110.000"–"+110.000"
"-165.000"–"+165.000"
ME-LPMSZ-SR-9
Remarks
Fixed value
• For CODE39, ITF, specify the
existence of check character.
• For NW-7, select start and stop
characters from A, B, C and
D and specify the existence of
check character.
Indicates the width of narrow
element of bar and space. Set the
larger value than "Line width" in
laser setting screen.
Specifies the center coordinate of
the code.
Ratio of quiet width to narrow
element width.
Ratio of wide element width to
narrow element width
• The correction ratio is calculated
using the value set at the laser
condition as 100%.
• With LP-SxxxW type, nothing
should be input in Laser Pulse
Cycle Correction.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents