3-2-3 Each command description in LP-F10/F10W mode
Reference
• The laser marker sends a response data after setting/readout command is transmitted.
• Refer to "2-5 Communication Data Format" (P.28)
■ Command mode setting: RSM
Switches between Standard mode and LP-F10/F10W.
Setting / Readout data of command mode
STX
RSM
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
Readout request of command mode
STX
RSM
Data length
Name
[byte]
Command
mode
Reference
• This command is valid only when the DIP switches are set to LP-F10 mode or LP-F10W mode.
• When the Remote mode is set to OFF or power is OFF, the mode returns to the initial value (LP-F10/LP-F10W mode).
120
Sub
[Command mode]
1-byte
R
(Check sum)
Description
"0": LP-F10/LP-F10W mode
1
"1": Standard mode
(Check sum)
Delimiter
ME-LPMSZ-SR-9
Delimiter
Remarks