■ Counter: CNT
Sets the counter conditions.
Setting / Readout data of counter condition
Sub
STX
CNT
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
Readout request of counter condition
STX
CNT
R
Data length
Name
[byte]
Counter No.
1
Current value
6
Initial value
6
End value
6
Step
6
Count source
1
Flag reset
1
Reference
• When marking on the flying object is valid, counter reset at re-dating timing cannot be used.
[Counter No.] [Current value] [Initial value] [End value]
[Step] [Count source] [Flag reset]
27-byte
[Counter No.]
1-byte
Description
"0"–"7"
"000000"–"999999"
"000000"–"999999"
"000000"–"999999"
"000000"–"999999"
"0": Counter 0
"1": Counter 1
"2": Counter 2
"3": Counter 3
"4": Counter 4
"5": Counter 5
"6": Counter 6
"7": Counter 7
"8": Trigger input
"0": Reset OFF at re-dating
"1": Reset ON at re-dating
ME-LPMSZ-SR-9
(Check sum)
Delimiter
"4"–"7": common counter
No minus number.
When the marking on the flying
object is valid, set "0".
(Check sum)
Delimiter
Remarks
51