Bar Code Marking Data (Ascii Code Specified) : Bbs; Setting / Readout Data Of Bar Code Marking Data; Readout Request Of Bar Code Marking Data - Panasonic LP-M Series Serial Communication Manual

Laser marker
Hide thumbs Also See for LP-M Series:
Table of Contents

Advertisement

■ Bar code marking data (ASCII code specified) : BBS

Sets character string to be encoded as a bar code or 2D code by ASCII code. For alphanumeric, symbols and specified
control codes (EOT/FS/GS/RS/US).

Setting / Readout data of bar code marking data

STX
BBS
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.

Readout request of bar code marking data

STX
BBS
Data length
Name
Bar code No.
Line No.
Bar code data
Max. 30
Reference
• When setting bar code marking data in multiple lines, data in each line are jointed in the order of line numbers and they
are coded as the data in one line. (No line break is inserted for each line.)
• When setting bar code marking data in multiple lines, the total input data should be 255 characters or less.
• If readout data includes function characters (such as "%SFT:0"), the setting character ("%SFT:0") is read out, but
characters to be actually marked are not.
• If readout data includes characters that cannot be expressed in ASCII code such as Katakana and Kanji (Shift-JIS Code
Specified), only these 2-byte characters are read out in shift-JIS code. In this case, the maximum readout data will be
34-byte or more.
• To input the control codes in the barcode/2D code strings, set the code data as follows:
• The following control codes EOT, FS, GS, RS, or US you can set by using ASCII code.
Control code
ASCII code (HEX)
• To include the control codes other than EOT, FS, GS, RS, or US in the strings, set the all control codes with BRS
command by using these 2-byte alternate codes instead of ASCII code.
• In the case that "GS1 Data Matrix" is selected as bar code type in bar code condition setting, the separator of
variable length AI data is inputted at GS (1D (HEX)) in this command. The separator is coded as "GS".
• For codes other than GS1 Data Matrix, the separator of variable length AI data "FNC1" cannot be set by this
command. Use BCS command or BRS command to set "FNC1".
56
Sub
[Bar code No.] [Line No.] [Bar code data]
Max. 34-byte
[Bar code No.] [Line No.]
R
Max. 4-byte
[byte]
2
"00"–"15"
1D code: "1"–"2"
1 or 2
2D code: "1"–"9"
2D part of Composite code: "01"–"09"
ASCII code characters within the range
from 04 (HEX) and 1C (HEX) to 7E (HEX).
(Functional characters should not be
included.)
EOT
FS
GS
04
1C
1D
(Check sum)
Description
RS
US
1E
1F
ME-LPMSZ-SR-9
(Check sum)
Delimiter
Delimiter
Remarks
Specifies the line for data setting.
Specifies the character setting in the
specified line.
Specify the data length with 0-byte in
order to delete the character string.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents