Functions; Screen Refresh Behavior For Overload - Only 840D Sl - Siemens SINUMERIK 840D sl Function Manual

Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

DB31, ... DBX94.5 (|n
The actual speed value n
DB31, ... DBX94.6 (n
The actual speed value is within the tolerance band (p2163) surrounding the speed setpoint.
DB31, ... DBX95.7 (warning of warning class C is pending)
The drive signals that a warning of warning class C is pending.
2.3

Functions

2.3.1

Screen refresh behavior for overload - only 840D sl

There are part programs, where the main run must wait until the preprocessing run provides
new blocks.
Preprocessing run and display refresh compete for NC processor time.
The following machine data can be used to set how the NC should behave if the preprocessing
run is too slow:
MD10131 $MN_SUPPRESS_SCREEN_REFRESH
Value
Meaning
0
If the preprocessing run of a channel is too slow, the display is not refreshed in all channels.
1
If the preprocessing run of a channel is too slow, the display is only refreshed in the time critical channels in order
to obtain processor time for the preprocessing run.
2
Display refresh is not suppressed.
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
| < n
)
act
x
act
= n
)
act
set
A2: Various NC/PLC interface signals and functions
is less than n
(speed threshold value 2, p2155).
x
2.3 Functions
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828dSinumerik 840de sl

Table of Contents