P3: Basic PLC program for SINUMERIK 840D sl
13.10 Structure and functions of the basic program
PROFIBUS connection on the MPI/DP port (MCPBusType = 4)
With the PROFIBUS connection of the MCP, this component must be considered in the STEP
7 hardware configuration. The MCP is connected on the MPI/DP bus of the PLC.
The addresses must be stored in the input and output log range. These start addresses must
also be stored in the pointer parameters of the FB1. The FB1 parameters listed below are used
for further parameterization. There is no PROFIBUS version of the HHU. For this reason, an
Ethernet connection is shown for the HHU in this diagram. The PROFIBUS slave address must
be stored in the parameters MCP1BusAdr and MCP2BusAdr. Enter the pointer to the
configured diagnostic address (e.g. P#A8190.0) in MCPxStatRec.
Figure 13-16 PROFIBUS connection on the MPI/DP port
Relevant parameters (FB1)
MCP
MCPNum = 1 or 2 (number of MCPs)
MCP1In
MCP1Out
MCP1StatSend (n.r.)
MCP1StatRec
MCP1BusAdr
MCP1Timeout
MCP1Cycl (n.r.)
MCPMPI = FALSE
MCP1Stop
MCPBusType = b#16#44
MCPSDB210= FALSE
MCPCopyDB77 = FALSE
874
MCP2In
MCP2Out
MCP2StatSend (n.r.)
MCP2StatRec
MCP2BusAdr
MCP2Timeout
MCP2Cycl (n.r.)
MCP2Stop
HHU
HHU = 5 (via CP 840D sl)
BHGIn
BHGOut
BHGStatSend
BHGStatRec
BHGInLen
BHGOutLen
BHGTimeout (n.r.)
BHGCycl (n.r.)
BHGRecGDNo
BHGRecGBZNo (n.r.)
BHGRecObjNo (n.r.)
BHGSendGDNo (n.r.)
BHGSendGBZNo (n.r.)
BHGSendObjNo (n.r.)
Function Manual, 01/2015, 6FC5397-0BP40-5BA2